Medium Voltage Copper Wire XLPE Insulated Power Cable

Model NO.: power cable
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001, CCC, RoHS, TUV BV Tis
Brand: Rmjt
Product Name: Medium Voltage Copper Wire XLPE Insulated Power Ca
Color of Sheath: Black Red or According to You
Standard: ASTM IEC DIN BS and So on
Medium Voltage: 11kv 8.7/15kv 22kv 25kv 30kv 35kv 36kv
Trademark: RMJT
Transport Package: Wooden/Steel Drum
Specification: 1.5mm2-800mm2
Origin: Henan, China
HS Code: 8544492100
Model NO.: power cable
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001, CCC, RoHS, TUV BV Tis
Brand: Rmjt
Product Name: Medium Voltage Copper Wire XLPE Insulated Power Ca
Color of Sheath: Black Red or According to You
Standard: ASTM IEC DIN BS and So on
Medium Voltage: 11kv 8.7/15kv 22kv 25kv 30kv 35kv 36kv
Trademark: RMJT
Transport Package: Wooden/Steel Drum
Specification: 1.5mm2-800mm2
Origin: Henan, China
HS Code: 8544492100
Medium Voltage Copper wire XLPE Insulated Power Cable
1.Application:
1)XLPE insulated copper power cable has a number of advantages compared with paper insulated and PVC insulate cables.
2)XLPE Copper cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level.
3) It can be applied in high temperature of 90 degree for a long time.
4)Flame-retardant and non-flame-retardant XLPE cables can be manufactured by three kinds of technological processes: peroxidation, silanization and irradiation.
5)The flame-retardant cable covers three classes of A, B, C and low-smoke low-halogen, low-smoke non-halogen cables.
Medium Voltage Copper Wire XLPE Insulated Power Cable
2.Standard:
Our XLPE Copper cable are produced according to IEC 60502, IEC60332, and IEC 60754, even some of our indexes are superior to the above international IEC standards. Meanwhile, we can produce cables according to other standards and can design the XLPE cables with some certain special properties according to customers' requirements.
XLPE Copper cable can be applied in high temperature for a long time and has bigger current capacity. In the same environment conditions, compared with paper insulated and PVC insulated cables, XLPE cable can lessen the cross section by 1 or 2 grades.

3.Specification:
1). Rated Voltage, No. of Core and Range of Sectional Area
Rated voltage (kv)
Sectional area (mm2)
No. of core
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35
1 Core   1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
2 Core   1.5-185 25-185            
3 Core   1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core   2.5-400 25-400            
5 Core   2.5-400 25-400            

 2).  DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
Nominal section area (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Copper core 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.099 0.0754 0.0601 0.047 0.0366 0.0283 0.0221
Aluminum core 18.1 12.1 7.41 4.61 3.08 1.91 1.2 0.868 0.641 0.443 0.32 0.253 0.206 0.164 0.125 0.1 0.778 0.0605 0.0469 0.0367

 3). Voltage Test and Partial Discharge Test
Rate voltage Uo (kv)
Item
0.6/1 1.8/3 3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 18/20 18/30 21/35 26/35
Voltage Test voltage 3.5 6.5 12.5 21 30.5 42 63 73.5 91
Test time 5 5 5 5 5 5 5 5 5
Partial discharge test Test voltage - - 6.2 10.4 15.1 20.8 31.1 36.3 45
Discharge capacity - - 10 10 10 10 10 10 10

Size
Nominal
thickness of
XLPE
insulation(mm)
Approx.
thickness of copper tape
screen (mm)
Nominal
thickness of
PVC or
PE(mm)
Approx. overall
diameter of finished
cable(mm)
Max. conductor D.C resistance @ 200C (Ω/km)
1x25mm2 3.4 0.12 1.8 20.3 0.727
1x35mm2 3.4 0.12 1.8 21.3 0.524
1x50mm2 3.4 0.12 1.8 22.4 0.387
1x70mm2 3.4 0.12 1.8 24.1 0.268
1x95mm2 3.4 0.12 1.8 25.7 0.193
1x120mm2 3.4 0.12 1.8 27.1 0.153
1x150mm2 3.4 0.12 1.8 28.7 0.124
1x185mm2 3.4 0.12 1.9 30.5 0.0991
1x240mm2 3.4 0.12 2.0 33.1 0.0754
1x300mm2 3.4 0.12 2.0 35.1 0.0601
1x400mm2 3.4 0.12 2.1 38.5 0.0470
1x500mm2 3.4 0.12 2.2 42.2 0.0366
1x630mm2 3.4 0.12 2.3 46.3 0.0283
1x800mm2 3.4 0.12 2.5 50.4 0.0221
Nominal Cross Section Approx. Overall Diameter of Conductor Nominal Thickness of XLPE Insulation Nominal Thickness of PVC Inner Sheath Diameter of Al Wires Nominal Thickness of PVC Outer Sheath Approx.Overall Diameter Approx. Weight
Cu Conductor Al Conductor
AWA AWA UnAr AWA UnAr AWA UnAr AWA UnAr AWA
mm2 mm mm mm mm mm mm mm mm kg/km kg/km kg/km kg/km
1.5 1.6 0.7 - - 1.4 - 5.7 - 44 - - -
2.5 2.0 0.7 - - 1.4 - 6.2 - 57 - - -
4 2.6 0.7 - - 1.4 - 6.7 - 74 - - -
6 3.1 0.7 - - 1.4 - 7.3 - 96 - - -
10 3.8 0.7 1.0 0.8 1.4 1.4 7.9 12.4 134 235 74 175
16 4.8 0.7 1.0 0.8 1.4 1.4 8.9 13.4 196 307 99 209
25 6.0 0.9 1.0 0.8 1.4 1.4 10.6 15.1 289 417 139 267
35 7.1 0.9 1.0 0.8 1.4 1.4 11.7 16.2 382 522 172 309
50 8.4 1.0 1.0 1.25 1.4 1.5 13.2 18.7 503 710 220 427
70 10.0 1.1 1.0 1.25 1.4 1.5 15.0 20.5 702 936 293 522
95 11.7 1.1 1.0 1.25 1.5 1.5 16.8 22.4 950 1209 384 638
120 13.3 1.2 1.0 1.6 1.5 1.6 18.6 25.1 1186 1531 469 806
150 14.5 1.4 1.0 1.6 1.5 1.6 20.4 26.7 1458 1820 567 923
185 16.4 1.6 1.0 1.6 1.5 1.7 22.7 29.2 1810 2219 698 1105
240 18.7 1.7 1.0 1.6 1.6 1.8 25.4 31.9 2348 2802 889 1335
300 20.4 1.8 1.0 1.6 1.7 1.8 27.4 33.7 2917 3393 1091 1568
400 23.2 2.0 1.2 2.0 1.8 2.0 30.9 38.5 3713 4377 1379 2043
500 26.4 2.2 1.2 2.0 1.9 2.1 34.7 42.3 4770 5512 1767 2510
630 30.0 2.4 1.2 2.0 2.1 2.2 39.1 46.5 6105 6914 2248 3058
800 34.0 2.6 1.4 2.5 2.2 2.4 43.6 52.6 7893 9008 2867 3981
1000 41.4 2.8 1.4 2.5 2.3 2.5 51.6 60.8 10189 11524 3690 5025
We could produce most of the standards cables, such as ASTM, BS, CSA, DIN, GB and IEC Standards, etc.
ISO9001:2008, OHSAS, CCC, TUV Certifications.
4.Production process:
Medium Voltage Copper Wire XLPE Insulated Power Cable
People's Cable Group Co., Ltd, a professional wires and cables manufacturer for 27 years in China. we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.
1. Factory: 160000 square meters, available for OEM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: TUV, OHSAS, CCC,  ISO9001:2008;
4. Guarantee: 20 years;
5. QC inspection: Strict inspection before delivery;
After-sales Service:
1. All our cables will be tested well in production and before delivery.
2. Please contact us if any problem, we will respond within 24 hours.

Contact us
Factory ADD: No. 13th, Yongding Road, Gongyi, Zhengzhou city, Henan Province, China.
TEL: +86-371-55632835
FAX: +86-371-55632837
Mobile: +86-18336390736
Sky:Tinaleeran
Medium Voltage Copper wire XLPE Insulated Power Cable
1.Application:
1)XLPE insulated copper power cable has a number of advantages compared with paper insulated and PVC insulate cables.
2)XLPE Copper cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level.
3) It can be applied in high temperature of 90 degree for a long time.
4)Flame-retardant and non-flame-retardant XLPE cables can be manufactured by three kinds of technological processes: peroxidation, silanization and irradiation.
5)The flame-retardant cable covers three classes of A, B, C and low-smoke low-halogen, low-smoke non-halogen cables.
Medium Voltage Copper Wire XLPE Insulated Power Cable
2.Standard:
Our XLPE Copper cable are produced according to IEC 60502, IEC60332, and IEC 60754, even some of our indexes are superior to the above international IEC standards. Meanwhile, we can produce cables according to other standards and can design the XLPE cables with some certain special properties according to customers' requirements.
XLPE Copper cable can be applied in high temperature for a long time and has bigger current capacity. In the same environment conditions, compared with paper insulated and PVC insulated cables, XLPE cable can lessen the cross section by 1 or 2 grades.

3.Specification:
1). Rated Voltage, No. of Core and Range of Sectional Area
Rated voltage (kv)
Sectional area (mm2)
No. of core
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35
1 Core   1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
2 Core   1.5-185 25-185            
3 Core   1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core   2.5-400 25-400            
5 Core   2.5-400 25-400            

 2).  DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.