Original Meanwell Lpc-60 Series Single Output Waterproof IP67 LED Driver
- Model NO.: LPC-60
- Output Type: DC
- Color: White
- Internal Structure: On-Off Type
- Connection: Screw
- Brand: Meanwell
- Trademark: Meanwell
- Specification: Universal
- HS Code: 8504401400
- Usage: Laptop, Switching, Mobile Phone, Game Player, Digital Camera, Phone, Display, LED Strip
- Certification: TUV, RoHS, UL, ISO9001, CCC
- Type: OEM
- Power Source: Full-Bridge Type
- Bluetooth Standard: 1.1
- Size: 162.5*42.5*32mm
- Transport Package: Paper Carton
- Origin: Guangdong China (Mainland)
Original Meanwell LPC-60 Series Single Output Waterproof IP67 LED Driver Features:
1. Constant voltage design
2. Universal AC input / Full range
3. Withstand 300VAC surge input for 5 seconds
4. Protections: Short circuit / Over load / Over voltage
5. Cooling by free air convection
6. Small and compact size
7. Fully encapsulated with IP67 level (Note.7)
8. Fully isolated plastic case
9. Class 2 power unit, no FG, Class 2 power unit
10. Pass LPS
11. Suitable for LED Lighting and moving sign applications
12. 100% full load burn-in test
13. Low cost, high reliability
14. 2 years warranty
Original Meanwell LPC-60 Series Single Output Waterproof IP67 LED Driver Specifications:
Â
MODEL | LPC-60-1050 | LPC-60-1400 | LPC-60-1750 | |
OUTPUT | RATED CURRENT | 1050mA | 1400mA | 1750mA |
DC VOLTAGE RANGE | 9 ~ 48V | 9 ~ 42V | 9 ~ 34V | |
RATED POWER | 50.4W | 58.8W | 59.5W | |
RIPPLE & NOISE (max.) Note.2 | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±5.0% | |||
CURRENT ACCURACY | ±5.0% | |||
LINE REGULATION | ±1.0% | |||
LOAD REGULATION | ±2.0% | |||
SETUP, RISE TIMEÂ Â Â Â Â Â Â Note.6 | 500ms, 120ms / 230VAC 500ms, 120ms / 115VAC at full load | |||
HOLD UP TIME (Typ.) | 50ms/230VACÂ Â Â 16ms/115VAC at full load | |||
INPUT | VOLTAGE RANGEÂ Â Â Â Â Â Â Note.4 | 90 ~ 264VACÂ Â Â 127 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
EFFICIENCY (Typ.) | 87% | 85% | 87% | |
AC CURRENT (Typ.) | 1.2A/115VAC 0.7A/230VAC | |||
INRUSH CURRENT(Typ.) | COLD START 60A(twidth=540μs measured at 50% Ipeak) at 230VAC | |||
MAX. No. of PSUs on 16A | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | |||
LEAKAGE CURRENT | 0.25mA / 240VAC | |||
PROTECTION | OVER VOLTAGE | 50.4 ~ 60V | 44.1 ~ 56.7V | 39.1 ~ 45.9V |
Protection type : Shut off o/p voltage, clamping by TVS diode | ||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70ºC (Refer to "Derating Curve") | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 ~ +80ºC, 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||
SAFETY & EMC |
SAFETY STANDARDS | UL1310, CAN/CSA C22.2 No. 223-M91(for LPC-60-1750 only), IP67, IEC60950-1:2005+A2:2013 approved ; design refer to TUV EN60950-1 | ||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |||
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25ºC/ 70% RH | |||
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 | |||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A | |||
OTHERS | MTBF | 732Khrs min. MIL-HDBK-217F (25ºC) | ||
DIMENSION | 162.5*42.5*32mm (L*W*H) | |||
PACKING | 0.4Kg; 32pcs/13.8Kg/0.56CUFT | |||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit. 8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute. |